For the Intermediate Line the GATECH HEC I (High End Controller I) is used. Every HEC I can store up to 10 different settings. The HEC I controls the air flows of the injector and the electrostatics of Corona dispenser.
If needed these controllers can be remote controlled by a PC through a CAN-BUS. All the parameters are displayed on the graphical display. Furthermore the units have a automatic cleaning I and automatic cleaning II for automatic or for manual dispenser and on request an additional connection to control a pinch valve.
Application features and benefits:
- Central operation and LCD display.
- Memory for 10 system configurations on stand alone unit.
- 2 air flow valves (injector).
- Easy to use
- 1 air flow valves for cleaning air and a pinch valve (Connection for pinch valve available August 2007).
- Set Value/Actual display for high voltage, air quantity, current limiter, memory used.
- 3 settings for current limiter, three stage cascade characteristic line setting.
- Automatic Cleaning I (automatic dispenser) and II (manual dispenser).
- High voltage control from 0 to 100 kV.
Technical Data:
- Weight: approx. 7 Kg
- Working temperature: +10°C +45°C
- Input voltage: 115V/230V +/- 10%
- Air pressure: max. 4 bar
- Water content: max. 1.3 g/Nmc max
- Oil content: max. 0.01 mg/Nmc max
- Air consumption: approx. 9 Nmc/h
| | |